Allen-Bradley SLC System
RockWell Allen-Bradley 1747 SLC? 500 PLC is a chassis-based, modular family of controllers and I/O. With multiple processor choices, numerous power supply options and extensive I/O capacity, the SLC 500 family provides a powerful solution for mid-range stand-alone or distributed industrial control. As one of the first full-featured small controllers on the market, it remains the gold standard in logic controllers more than a decade after its introduction.
Features
Up to 64 K words of configurable data and program memory
Control up to 4096 input and 4096 output signals
Configure up to three local chassis, with 30 local I/O or communication modules maximum
Monitor and control remotely located I/O across ControlNet?, DeviceNet?, and Universal Remote I/O links (requires I/O scanner module)
Built-in ports for EtherNet/IP?, DH+, DH-485, or RS-232 communication
Available communication modules provide additional communication options
Specialty modules support simple motion control applications
Continued support and on-going engineering investment for a large installed base
Products
1747 SLC? 500 Controllers
1746 SLC I/O
1746 Chassis
1747 Communication Interface Modules
1746 Power Supplies
Certifications
UL, C-UL, CE, C-Tick
Certifications apply when product is marked. See our Product Certification site for Declarations of Conformity, certificates and other certification details.
Chassis
Allen-Bradley SLC PLC System 1746 SLC? 500 Power Supplies provide power to installed controllers or adapters and I/O modules in an SLC chassis. Seven power supplies support a range of AC and DC input voltages.
Allen-Bradley SLC? 500 system requires a chassis to contain the various modules. Chassis are available in sizes of 4, 7, 10, and 13 module slots. The backplane provides a communication path between the I/O modules and either the controller or the I/O adapter module.
Communication Interfaces
Allen-Bradley SLC PLC System 1747 SLC? 500 Communication Interface Modules let you add another communication port to the SLC 500 controller. This adds network capability beyond the available on-board ports. Some modules provide an interface between a port on the controller and another communication link with a different protocol. Other modules communicate with the SLC processor over the system backplane.
Controllers
Allen-Bradley SLC PLC System 1747 SLC? 500 controllers provide a range of choices in memory, I/O capacity, instruction set,
ALLEN-BRADLEY SLC 500 PLC SYSTEM
and communication ports to let you tailor a control system to your exact application requirements. Our controllers have a strong reliability history covering hundreds of thousands of installations in a broad range of applications.SLC 500 Controller Comparison:
Controller Series | Instruction Memory Words | Max. I/O Points | I/O Options | Built-in Ports | Additional Features |
SLC 5/01 | 1 K or 4 K | 960 | Local I/O | DH-485 (cannot initiate messages) | Basic set of 51 instructions |
SLC 5/02 | 4 K | 4096 | Local I/O, remote I/O | DH-485 | Expanded instruction set, faster scan times, extensive diagnostics for more complex applications |
SLC 5/03 | 8 K, 16 K, or32 K | 4096 | Local I/O, remote I/O | DH-485, RS-232-C (ASCII or DF1) | Connects to external intelligent devices using the RS-232 port, without additional modules |
SLC 5/04 | 16 K, 32 K, or 64 K | 4096 | Local I/O, remote I/O | DH+, RS-232-C (ASCII or DF1) | High-speed peer-to-peer communications and direct connection to PLC-5 controllers |
SLC 5/05 | 16 K, 32 K, or 64 K | 4096 | Local I/O, remote I/O | Ethernet (10BASE-T 10/100 Mbps), RS-232-C (ASCII or DF1) | Ethernet supports program upload and download, on-line editing, and peer-to-peer messaging |
Allen-Bradley SLC PLC System 1747, Please contact our sales personnel.
SLC 500 I/O Modules
SLC I/O
Allen-Bradley SLC PLC System 1746 SLC? I/O provides a full range of digital, analog, and specialty I/O for a wide variety of applications. You can use the I/O modules in a local I/O chassis of an SLC 500 controller. Or, use an I/O communication adapter module to place I/O in a chassis at a location remote from the controller.
1746 SLC Digital I/O Modules,1746 SLC Analog I/O Modules,1746 SLC Specialty I/O Modules,1746 SLC Communication Interfaces
Power Supplies
Bulletin 1746 SLC? 500 power supplies provide power to
SLC 500 Power Supplies
installed controllers or adapters and I/O modules in an SLC chassis. Seven power supplies support a range of AC and DC input voltages.
Withstands brief power losses without affecting the operation of the system
Typical hold-up time of 20 milliseconds to 3 seconds
Connects directly to the chassis without an additional cable
Four DC options support 12/24V DC, 24V DC, 48V DC and 125V DC input voltages
Three AC options support 120/240V AC input voltages
SLC System Software
RSLogix 500
Use RSLogix 500 programming software software to program your SLC? 500 system.
The controller and modules you select, along with your network configuration, determine which additional software packages you need to configure and program your system. Additional required softwar